Fate of Pharmaceuticals during Wastewater Treatment by a Membrane Bioreactor

This study provides a comprehensive insight into the levels and fate of nine commonly used pharmaceuticals (amitriptyline, atenolol, gemfi brozil, ibuprofen, ketoprofen, metformin, naproxen, paracetamol and simvastatin) through a full-scale membrane bioreactor (MBR) in New South Wales, Australia. Seven out of the nine studied pharmaceuticals were detected in the raw sewage with average concentrations in the range of 1.29– 33.3 μg.L–1, while gemfi brozil and simvastatin were below the analytical detection limit (1 ng.L–1). The MBR consistently achieved high removal effi ciencies of the detected pharmaceuticals, in the range of 77.2–99.9 %. A mass-balance showed that sorption to biomass was the dominant removal mechanism for amitriptyline while biodegradation/ transformation was responsible for removing all other pharmaceuticals. This study revealed that log D (Log Kow corrected for ionisation at the ambient pH) provides an effective estimation of the sorption capacity of these pharmaceuticals to biomass.

Submerged membrane bioreactors (MBRs) are favoured technology for sewage treatment in small communities. This is due to their small footprint and the ability to produce high quality effl uent, which is suitable for water reuse. MBRs have achieved excellent removal effi ciencies with respect to pathogens, suspended solids, organics and nitrogen [1]. Recently, interest into the ability of MBRs to eliminate trace organic chemicals such as pharmaceuticals has increased [2–5]. Pharmaceuticals are of concern for water recycling schemes because of their widespread use by the public and their potential for adverse environment and public health eff ects [6-10]. The fate of pharmaceuticals during MBR treatment is complex and includes biodegradation/ transformation and/or partitioning to either solid or liquid phases. To date, the majority of studies which have characterised the removal of pharmaceuticals by MBRs have focused on measuring pharmaceuticals within the aqueous phase, with little consideration of the solid phase (i.e. biomass). To better understand the fate and removal mechanisms of pharmaceuticals through MBRs, both aqueous and solid phases of the MBR need to be investigated.



Copyright: © DIV Deutscher Industrieverlag GmbH
Source: GWF international 2011 (September 2011)
Pages: 5
Price: € 5,00
Autor: Trang Trinh
Ben van den Akker
Heather Coleman
Stuart Khan
Pierre Le-Clech

Send Article Add to shopping cart Comment article


These articles might be interesting:

Breites Leistungsspektrum
© Rhombos Verlag (3/2019)
Für die Phosphorrückgewinnung aus Abwasser und Klärschlamm stehen aus technischer und ökonomischer Sicht verschiedene Verfahren zur Verfügung

Kommunale Wasserdienstleistung in trockenen Tüchern
© Springer Vieweg | Springer Fachmedien Wiesbaden GmbH (7/2018)
Trinkwasserversorgung und Abwasserbeseitigung müssen langfristig sicher sein. Dies erfordert die Bewertung und Steuerung von Gefahrenpotenzialen und Risiken. Daher wurde ein Nachhaltigkeitscontrolling für siedlungswasserwirtschaftliche Systeme entwickelt.

„Das Kompetenzzentrum Spurenstoffe Baden-Württemberg hat die Entnahme von Spurenstoffen aus dem Abwasser im Fokus“
© Springer Vieweg | Springer Fachmedien Wiesbaden GmbH (6/2016)
Das Kompetenzzentrum Spurenstoffe – KomS – sammelt und bündelt in Baden-Württemberg Wissen und Betriebserfahrungen zu den Themen Spurenstoffe wie Arzneimittel oder hormonell wirksame Substanzen im Abwasser und möglichen Verfahrenstechniken zu deren Elimination. WASSER UND ABFALL sprach mit seinem Leiter Herrn Dr. Steffen Metzger über Ziele und Aktivitäten des Kompetenzzentrums.

Ozonung für die Abwasserdesinfektion und Spurenstoffentfernung
© Springer Vieweg | Springer Fachmedien Wiesbaden GmbH (5/2016)
Eine Ozonung des gesamten Abwasserstromes einer kommunalen Kläranlage sowohl betrieblich wie auch wirtschaftlich möglich.

Erhöhte Anforderungen an die Phosphatelimination auf Kläranlagen
© Springer Vieweg | Springer Fachmedien Wiesbaden GmbH (5/2016)
Durch die konsequente Umsetzung der EU-WRRL werden im Ablauf von Kläranlagen vermehrt sehr niedrige Pges-Ablaufwerte gefordert. Neben der einzusetzenden Verfahrenstechnik und der Zusammensetzung des Rohabwassers sind zur Bewertung der Leistungsfähigkeit auch Probenart und Auswertungssystematik von Bedeutung.

Username:

Password:

 Keep me signed in

Forgot your password?